Use the correct discharge rate
A battery rated 100Ah at a long discharge period delivers less capacity during a short, high-current outage.
NP Series · 6V and 12V standby power
A broad sealed AGM range from compact 1.3Ah units to 250Ah batteries for UPS, emergency lighting, security, telecom and industrial standby applications.

Product range
NP Series uses AGM technology and is catalogue-listed with a five-year design-life statement and UL reference MH28022. The family spans 6V 1.3–200Ah and 12V 1.3–250Ah. Capacity is published at 25°C and 1.75V per cell across different discharge rates, so buyers should compare the capacity at their actual runtime—not only the 20-hour Ah label.
Model comparison
These figures are transcribed from the catalogue revision identified with the product image. Request the current model datasheet before approval or purchase.
| Representative model | Rating | Size L×W×H (mm) | Weight | 1-hour capacity | 10-hour capacity | 20-hour capacity |
|---|---|---|---|---|---|---|
| NP7-12 | 12V 7Ah | 151 × 65 × 94 | 2.3kg | 4.2Ah | 6.8Ah | 7.0Ah |
| NP18-12 | 12V 18Ah | 181 × 76 × 165 | 5.4kg | 9.9Ah | 17.0Ah | 18.0Ah |
| NP38-12 | 12V 38Ah | 197 × 165 × 170 | 13.3kg | 22Ah | 38Ah | 40Ah |
| NP100-12 | 12V 100Ah | 328 × 172 × 214 | 30.5kg | 59Ah | 100Ah | 110Ah |
| NP200-12 | 12V 200Ah | 522 × 240 × 218 | 61.5kg | 115Ah | 200Ah | 220Ah |
| NP250-12 | 12V 250Ah | 520 × 269 × 220 | 76kg | 140Ah | 250Ah | 270Ah |
Product selection
Available project information is enough for an initial model shortlist and document response.
A battery rated 100Ah at a long discharge period delivers less capacity during a short, high-current outage.
Confirm float voltage, recharge current, temperature compensation and low-voltage disconnect settings.
Verify total height, terminal type, cable orientation and service clearance before choosing a nominally equivalent model.
Typical applications
Product matching is based on the equipment, duty cycle and installation conditions supplied with the inquiry.
Calculate load and runtime at the relevant discharge rate, then check recharge time.
Review standby duration, inspection interval and end-of-discharge voltage.
Confirm cabinet temperature, DC voltage, autonomy and remote monitoring boundary.
Commercial information
Availability, documents and commercial terms are provided against the requested model, quantity and destination.
For an accurate quote
Product FAQ
We will confirm current availability, documents and commercial terms for the exact model you select.
It is capacity measured over a long discharge period under stated conditions. Shorter runtimes produce a lower available Ah value, as the catalogue rate columns show.
It is primarily positioned as an AGM standby family. Repeated cycling should be reviewed against the NPL, GM or GEL families.
Only after checking charger capacity, recharge time, fault current, case size, weight and cable protection.
The catalogue describes NP Series as AGM technology with a five-year design life. Actual service depends on temperature, charging and duty.
Provide voltage, load, runtime, space and terminal requirement so the shortlist uses the correct discharge-rate capacity.
Product inquiry
Send the available application, voltage, load, runtime, installation space, quantity and destination.