NPF Series · 12V 55–155Ah

Front-Terminal Telecom Battery

Tall, narrow front-terminal VRLA batteries designed for service access in telecom and network cabinets, with six catalogue capacities from 55Ah to 155Ah.

CATALOGUE MANUFACTURING SOURCEGuangdong Zhicheng Champion Group Co., Ltd.Product selection and export inquiry contact: Sodium Energy Systems
Champion NPF front-terminal telecom VRLA batteries with tall narrow cases
CROPPED PRODUCT IMAGE · CHAMPION LEAD-ACID BATTERY CATALOGUE 2023
VOLTAGE12V
CAPACITY RANGE55–155Ah
CASE WIDTH106–109mm
DESIGN-LIFE STATEMENTUp to 8 years

Product range

Models, ratings and installation differences

NPF Series places terminals at the front of a narrow 106–109mm case for rack and cabinet access. The catalogue lists 12V 55Ah, 80Ah, 100Ah, 120Ah, 125Ah and 155Ah models, an eight-year design-life statement, flame-retardant case availability and UL reference MH28022. Capacity still varies with discharge rate, so autonomy must be calculated from the required outage duration.

Model comparison

Compare the ratings that affect your installation.

These figures are transcribed from the catalogue revision identified with the product image. Request the current model datasheet before approval or purchase.

ModelRatingSize L×W×H (mm)Weight1-hour capacity10-hour capacity20-hour capacity
NP55-12-F12V 55Ah277 × 106 × 22318kg33Ah55Ah58Ah
NP80-12-F12V 80Ah394 × 109 × 28628kg48Ah80Ah86Ah
NP100-12-F12V 100Ah394 × 109 × 28634kg60Ah100Ah107Ah
NP120-12-F12V 120Ah551 × 109 × 23938kg72Ah120Ah128Ah
NP125-12-F12V 125Ah551 × 109 × 28842kg77Ah125Ah135Ah
NP155-12-F12V 155Ah551 × 109 × 28850kg97Ah150Ah165Ah

Product selection

Load, charger and installation details

Available project information is enough for an initial model shortlist and document response.

01

Start with cabinet depth

Confirm length, height, terminal clearance and removal path; all models are narrow, but not the same length or height.

02

Calculate autonomy at the right rate

A 100Ah model provides a catalogue-listed 60Ah at the one-hour rate, not 100Ah.

03

Plan string service

Define series count, string redundancy, breaker or fuse arrangement, cable access and replacement procedure.

Typical applications

Applications for this battery family

Product matching is based on the equipment, duty cycle and installation conditions supplied with the inquiry.

01

Telecom base stations

Review DC bus, outage duration, rectifier settings, cabinet temperature and remote alarms.

02

Network and data cabinets

Confirm front access, footprint, discharge current and maintenance window.

03

Remote-site backup

Account for temperature, service intervals, recharge availability and transport access.

Commercial information

Current purchasing details for the selected model

Availability, documents and commercial terms are provided against the requested model, quantity and destination.

01MOQ and sample availability02Current production lead time03Model datasheet and available certificates04Packing, shipment and Incoterm options05Warranty basis and claim process06OEM branding or configuration options

For an accurate quote

Send these details if available

  1. 01DC bus voltage, number of blocks per string and redundancy
  2. 02Continuous load, peak load and required backup duration
  3. 03Rectifier or charger settings and cabinet temperature
  4. 04Cabinet depth, shelf load, terminal clearance and front-removal path
  5. 05Current exact-model data, UL scope and transport documentation
Telecom Backup Selection Guide→AGM VRLA Battery→High-Temperature VRLA Battery→Request a Quote→

Product FAQ

Questions buyers ask before ordering

We will confirm current availability, documents and commercial terms for the exact model you select.

Why use a front-terminal battery?+

It keeps terminal and connection access at the cabinet front, reducing the need to reach behind a deep battery block.

Which models share the same case?+

NP80-12-F and NP100-12-F share the listed 394 × 109 × 286mm size; NP125-12-F and NP155-12-F share 551 × 109 × 288mm.

How do I estimate one-hour backup?+

Use the one-hour capacity column and the actual end voltage, then include aging, temperature and design margin.

Is a flame-retardant case standard?+

The catalogue says a flame-retardant case can be made. Confirm the exact case material and document for the ordered model.

Can these batteries be used outside telecom?+

They can suit other narrow-rack standby applications, but voltage, charge profile, runtime and installation must be qualified.

Product inquiry

Request product data, availability or a quotation.

Send the available application, voltage, load, runtime, installation space, quantity and destination.