Define depth of discharge
State the normal and maximum DOD, cycles per day, autonomy and time available for recharge.
NPL · GM · repeated cyclic duty
Two distinct deep-cycle routes: NPL 6V/12V AGM batteries for conventional case formats and GM 2V cells for larger stationary banks.

Product range
NPL Series is catalogue-described as a high-tin, eight-year design-life AGM family and mirrors a wide set of 6V and 12V capacities. GM Series uses a thick-plate 2V design from 50Ah to 3000Ah with a 10-year catalogue design-life statement. They are not interchangeable: NPL suits conventional multi-battery arrangements, while GM cells support larger stationary strings and require rack, inter-cell connection and installation planning.
Model comparison
These figures are transcribed from the catalogue revision identified with the product image. Request the current model datasheet before approval or purchase.
| Series / model | Rating | Size L×W×H (mm) | Weight | 1-hour capacity | 10-hour capacity | Design-life statement |
|---|---|---|---|---|---|---|
| NPL / NP55-12-L | 12V 55Ah | 228 × 137 × 208 | 18.6kg | 32Ah | 55Ah | 8 years |
| NPL / NP100-12-L | 12V 100Ah | 328 × 172 × 214 | 30.5kg | 59Ah | 100Ah | 8 years |
| NPL / NP200-12-L | 12V 200Ah | 522 × 240 × 218 | 61.5kg | 115Ah | 200Ah | 8 years |
| GM100-2 | 2V 100Ah | 171 × 72 × 205 | 6.7kg | 58Ah | 100Ah | 10 years |
| GM600-2 | 2V 600Ah | 301 × 175 × 331 | 34.8kg | 336Ah | 600Ah | 10 years |
| GM1500-2 | 2V 1500Ah | 401 × 351 × 342 | 83.5kg | 840Ah | 1500Ah | 10 years |
Product selection
Available project information is enough for an initial model shortlist and document response.
State the normal and maximum DOD, cycles per day, autonomy and time available for recharge.
The system voltage, bank capacity, rack, maintenance access and replacement strategy drive the architecture.
Select from the capacity at the expected discharge duration and end voltage, then include aging and temperature margin.
Typical applications
Product matching is based on the equipment, duty cycle and installation conditions supplied with the inquiry.
Size from daily load, autonomy and recovery energy—not only array capacity.
Confirm peak current, vibration, charging opportunity and physical restraint.
Plan racks, inter-cell links, protection, ventilation and string monitoring for larger 2V banks.
Commercial information
Availability, documents and commercial terms are provided against the requested model, quantity and destination.
For an accurate quote
Product FAQ
We will confirm current availability, documents and commercial terms for the exact model you select.
NPL is a 6V/12V AGM block family; GM is a 2V thick-plate cell family for larger stationary banks.
Lead-acid available capacity falls as discharge rate increases. Select using the runtime column closest to the application.
No. Cycle life depends strongly on DOD, temperature, charge recovery and time spent partially charged.
Possibly, but charger settings, space, terminals and duty must be reviewed. The key benefit is alignment with repeated cycling.
Provide load, runtime, cycles per day, DOD, recharge source, temperature, voltage and available installation space.
Product inquiry
Send the available application, voltage, load, runtime, installation space, quantity and destination.