Choose sealed or flooded deliberately
NPFG reduces routine electrolyte access; OPzS requires ventilation, electrolyte and maintenance planning.
Stationary GEL and flooded tubular routes
Two long-duration stationary choices that must not be treated as the same product: sealed front-terminal GEL NPFG blocks and serviceable flooded OPzS tubular cells.

Product range
The supplied catalogue page does not show a separate OPzV model table; it shows NPFG front-terminal GEL 12V models from 55Ah to 155Ah and OPzS flooded tubular 2V cells from 150Ah to 1000Ah. OPzS is listed with a 15-year floating design-life statement and more than 1,000 deep cycles. Because OPzS is flooded, electrolyte, ventilation and maintenance planning differ materially from sealed GEL products.
Model comparison
These figures are transcribed from the catalogue revision identified with the product image. Request the current model datasheet before approval or purchase.
| Family / model | Rating | Size L×W×H (mm) | Dry / filled weight | 1-hour capacity | 10-hour capacity | Construction |
|---|---|---|---|---|---|---|
| NPFG / NP55-12-FG | 12V 55Ah | 277 × 106 × 223 | 18kg | — | 51Ah | Sealed front-terminal GEL |
| NPFG / NP155-12-FG | 12V 155Ah | 551 × 109 × 288 | 50kg | — | 145Ah | Sealed front-terminal GEL |
| OPzS-150 | 2V 150Ah | 103 × 206 × 355 | 10.5 / 15kg | 57Ah | 150Ah | Flooded tubular |
| OPzS-300 | 2V 300Ah | 145 × 206 × 355 | 19.2 / 24.3kg | 115Ah | 300Ah | Flooded tubular |
| OPzS-600 | 2V 600Ah | 145 × 206 × 646 | 33.9 / 44.8kg | 213Ah | 600Ah | Flooded tubular |
| OPzS-1000 | 2V 1000Ah | 233 × 210 × 646 | 55.5 / 74.6kg | 355Ah | 1000Ah | Flooded tubular |
Product selection
Available project information is enough for an initial model shortlist and document response.
NPFG reduces routine electrolyte access; OPzS requires ventilation, electrolyte and maintenance planning.
Define DC voltage, cell count, autonomy, end voltage, redundancy and rack footprint.
Check floor loading, spill control, ventilation, inter-cell links, access and lifting before quotation.
Typical applications
Product matching is based on the equipment, duty cycle and installation conditions supplied with the inquiry.
Long-duration stationary DC systems with defined inspection and maintenance practice.
Projects with repeated cycling, autonomy and a battery room designed for the chosen construction.
NPFG may fit front-access cabinets; OPzS may fit larger maintained stationary rooms.
Commercial information
Availability, documents and commercial terms are provided against the requested model, quantity and destination.
For an accurate quote
Product FAQ
We will confirm current availability, documents and commercial terms for the exact model you select.
No separate OPzV table is identifiable in the supplied pages. The published comparison therefore uses NPFG sealed GEL and OPzS flooded tubular models and requires a separate current OPzV document for an OPzV quotation.
NPFG is sealed front-terminal GEL in 12V blocks; OPzS is a flooded tubular 2V cell requiring a maintained installation.
The catalogue lists 2V models from 150Ah through 1000Ah.
The catalogue states 15 years design life in floating condition and more than 1,000 deep cycles.
Flooded OPzS cells add electrolyte weight at installation, which affects handling, rack and floor loading.
Product inquiry
Send the available application, voltage, load, runtime, installation space, quantity and destination.